You are at ULMA Polymer Concrete > Products >Drainage > Installation Instructions > Table I: Thickness of concrete bedding

Installation Instructions

Table I: Thickness of concrete bedding

Load according to Standard EN-1433
X
Minimum side thickness (mm.)
Z
Minimum thickness  of base (mm.)
Y
Height of side form
Recommended wire mesh (cmxcmxmm) Type of concrete (Kg/cm2)
A-15 100 100 At least at a point located at 40 mm below the level of the pavement.   150
B-125 100 100   250
C-250 150 150 Up to the level of the wire mesh and the adjoining pavement.   250
D-400 150 150 15 x 15 x 6 250
E-600 150 150 15 x 15 x 10 250
F-900 200 200 15 x 15 x 12 250
Detalle del espesor del dado de hormigon Detalle del espesor del dado de hormigon